Quantcast
Channel: SCN : Discussion List - SAP for Utilities
Viewing all articles
Browse latest Browse all 2484

How to get the INFACT06 Variant value Reversal in Dynamic Period Control

$
0
0

Hi,

     In our Requirement whenever Export Energy Quantity is Greater than Import Energy Quantity the Difference should be added in Installation Facts with the help of INFACT06 Variant. We are using Dynamic Period Control because of that we are getting wrong Consumption values whenever below given Scenario happens.

 

 

 

 

Actual Read

Estimated Read

Actual Read

Import : 2000 (500 Units)

Import : 2500 (500 Units)

Import : 2400 (400 Units)

Export  :  1000 (-300 Units)

Export   : 1800 (-800 Units)

Export  : 1700 (-700 Units)

Billing   : 500 + (-300) = 200 units

Billing : 500 + (-800) = -300

Billing : 400 + (-700-300) = -600

 

 

In the Last Month's Estimated Bill the Difference Between the Export Energy and Import Energy Consumption of 300 Units is saved in the Installation Fact and that value is getting added in the Next Month's Actual Read of Export Energy Consumption Where as it shouldn't.

 

 

We need to Restrict INFACT06 Variant value of Estimated Month getting added in Next Month's Actual Reads. Suggestions Please.

 

Thanks.

Karthick


Viewing all articles
Browse latest Browse all 2484

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>